Integrity test

Integrity test

+370 686 21397 andrius@namuinspektorius.lt

Integrity test

  • Enclosure integrity test
  • International license
  • Certified professionals
  • The only in Lithuania


Water-based fire extinguishing systems only provide primary fire extinguishing by sacrificing the property is that the premises. Archives, servers, data centres, exhibits, cable channels, other expensive assets and engineering in buildings are destroyed or damaged by water. For this reason, a need for gas extinguishing systems has emerged. In order to ensure the efficiency of such gas extinguishing systems, in-house systems testing and modelling are required.

The Integrity test determines the tightness of the room, the area of leakage, the possible time of gas concentration retention, the peak pressure, and the effectiveness of safety valves. In the case of unacceptable results, all leaks are detected with a smoke generator, thermovision or ultrasound, and a recommendations for rectification of defects str made.

This test is carried out only by certified technicians using calibrated equipment as well as by an accredited laboratory.

Our specialists not only carry out the tests, but also consult at the design stage of such premises.

Services are performed in accordance with NFPA and ISO standards.

Trusted by Our Clients

Client testimonials

A professional approach – thermal bridge calculations and dynamic modeling were particularly useful.
Darius V.
Precise calculations made it possible to optimize materials and avoid overpaying for oversized equipment.
Rasa M.
Detailed energy modeling helped precisely achieve the required energy performance class.
Tomas K.

Our Certificates

Our work is carried out in accordance with applicable regulations and the qualifications and certifications we hold.

Retrotec Enclosure Integrity Certification – Level 2 (2020)

Retrotec Enclosure Integrity Certification – Level 2 (2020)

Certificate confirming qualification in enclosure integrity testing and peak pressure assessment using Blower Door equipment, in accordance with NFPA 2001, ISO 14520, and EN 15004 standards.

View certificate

Frequently Asked Questions

When to start energy modeling?
Having pre-design proposals, preliminary energy calculations can already be prepared.
Are the calculations further refined after the initial assessment?
Yes, after the initial assessment, the energy model is further refined.
Are thermal bridges calculated?
Yes, they are. They typically have a significant impact on the overall project.
Can you achieve cost savings through energy calculations?
Yes, the savings can be significant, as precise calculations prevent unnecessary over-specification of materials.
Does energy design help meet the demand for green electricity?
Yes, with a high-quality energy assessment of the project, the minimum required capacity of the solar power plant will also be calculated.

Let's Talk About Your Project!

Contact us for professional advice and a tailored quote for your building’s energy performance modelling or thermal bridge calculations.

+370 686 21397 andrius@namuinspektorius.lt